Ethernet Multi-Session Offload Recorder#
Purpose#
Offloads multiple stored sessions from ECUs that support multi-session memory (e.g. TAG-310).
Prerequisites#
ECU must support multi-session (BIOS B023+).
ATLAS or ADS must be running.
Setup Instructions#
-
Open Session Browser.
-
Add an Ethernet Multi-Session Offload Recorder.
-
Use the Connection Tab to:
-
Select Car and Unit.
-
Choose SQL Server or SQLite.
-
Set Export Folder.
-
Define Session Identifier.
-
Use the Select Sessions Tab to:
-
View sessions stored on the ECU.
-
Select sessions to offload.
-
Use buttons: Select All, Clear All, Hide Offloaded, Query.
-
-
Click Start to offload selected sessions.
Notes#
Sessions with overlapping timestamps are grouped into one SQL Race session. If the unit doesn’t support multi-session, use the standard Ethernet Telemetry Recorder